CE Certified 18L Class N High Pressure Dental Autoclave Sterilizer Manufacture
Description:
Dental Autoclave Sterilizer are designed to use high pressure and high temperature steam to kill microorganisms. They are also used to render biohazardous materials inactive. For the steam autoclave to be effective, the materials to be sterilized must be saturated with steam. If there isn’t enough steam or air pockets exist in the materials, decontamination will not take place.
Essentially an autoclave is a pressure cooker that uses steam under pressure as its sterilizing agent. The increase in pressure (above atmospheric pressure) enables steam to reach higher temperatures. The extra pressure brings the boiling temperature of water higher. In fact, around 20°C higher. This effectively increases its heat content and killing ability. This comes from its latent heat of evaporation. The latent heat of evaporation is the amount of heat that is required to convert boiling water to steam. This conversion heat is quite large compared to the amount of heat that is required to make water hot.
Specification:
Input power : AC110V , 60±1Hz / AC220V , 50±1Hz
Capacity: 18 liter
Machine size :(L)58 X (W)39 X(H) 36 CM
Packing size : (L)64 X (W)44 X(H) 36.5 CM
Power: 900VA(W)
Sterilization temp and time : 121°C / 25 MIN; 134C / 6 MIN
Operating ambient temperature : 5~ 40°C
Security : main board load protection / door safety switch temp overload protection switch / safety valve
Fuse (13A/05*25mm)
Dental Autoclave Sterilizer technical data:
Chamber Size | Φ250*D350 / 18Liter |
Using Tem and Pressure | 122 degree / 1.12kg/cm2 & 134 degree / 2.1kg/cm2 |
Sterilize Time | 122℃ / 25min and 134 ℃ / 6min |
Voltage | 220V,50Hz or 110V,60Hz |
Use Step:
Step 1: Put 800ml Distilled water into the chamber.
Step 2: put sterilization instrument in the tray.
Step 3: Close the door and insert the bolt
Step 4: Close the steamexhaust switch.
Step 5:Select the temperature (121℃ or 134℃)
Step 6:Turns on the POWER switch.(starts to work)
Disinfect Process
Heating
----First emissions steam
----Second emissions steam
-----The temperature rise arrives at the disinfection temperature
----Starts to disinfect
----The disinfection completes
----Buzzer sound
-----The buzzer stops the sound
-----Turns on the steam emissions switch
----Waited for that the Pressure gauge nulling operation
----Waits for 6~8 minutes
----Opens the door
----The disinfection completes