18L LCD Dental Autoclave Sterilizer Class B Low Vacuum Ability
Pressure/Temperature | 0.9~1.3bar/121℃;2.0~2.3bar/135℃ |
Test Program | Bowie&Dick test, Helix test, Vacuum test |
Sterilizing Data | Print by optional external mini-printer or download USB port |
Safety Features | Safe Valve;Double-control lock system and self-test alam system |
Special Function | Kill the AIDS (HIV), hepatitis B (HBV) mad cow virus and Bacillus |
Instrument Containers | 5-layer activity pallet rack with 3 trays |
Chamber Size | 250mm*355mm |
Features:
1.Steam generator and bolier heating separated.
We adopt the Steam generator to produce steam, for let the steam generation and boiler heating
separated, so that we can manipulate the speed and volume of steam generated, reducing the water
consumption,and also improved the lifetime of heating circle because of the lower temperature of bolier.
2.The material of Lid safe&reliable
Adopt the imported 2mm SU304 stainless steel. It will be safe when the inside chamber have a higher
pressure and also there will avoid the second times pollution which casued by the corrosion from the Lid.
3.Advantages of the control system
The Getidy company research&developed the new temperature and pressure control technology by
myself to ensure the Positive and negative temperature of every two points inside chamber less than 0.5
℃, guarantee complete sterilization.
4.The reliability of measurement accuracy
The measurement accuracy of temperature:0.5℃,The measurement accuracy of pressure :0.1bar.
5.The safty of double-control lock structure
Use the newest Machinery and electronic double-control lock structure,to be sure the safty durning the
operation time.
6. Low enough vacuum ability
Use the double-head vacuum pump,let the each pulse vacuum process achieve low enough vacuum,
guarantee complete sterilization.
7. Automatical & manual adjust of the parameters of temperature sensor
The adjust of parameters is automatical, and manual adjust is also available on your will.this way can
sure the machine can work in different atmospheric environments
8. Multilanguage are optional,Easy to operate
The users can find the language according his requestes,easily.
9. Broad ventilation window design, convenience& fast of heat radiation
Maintanence
1 clean the fresh water storage tank every week with medical disinfectant constantly. Drain the distilled water out in the water storage tank, then pour medical disinfectant in and hold it for an hour, clean it with distilled water at last.
2. Sterilizer and clean the chamber once a month with medical ethyl alcohol.
3. Replace the blown fuse
4. Cut off the electricityTurn the fuse board counterclockwise with a screw-driver, and pull the blown fuse out.
5. Replace the blown fuse with a new one, put the fuse board back and install it back by turning it clockwise with a screw-driver.
6. Make sure the parameter of new fuse is OK.